Seria HI2000 de sonde ORP digitale sunt senzori industriali utilizați pentru aplicații de monitorizare și control. Aceste sonde sunt disponibile in multiple configuratii, joncțiune de referință ceramică sau PTFE și material pentru senzori din platină sau aur. Toate sondele au un senzor de temperatură pt100 încorporat și au un corp din PVDF rezistent chimic, care are filete NPT de ¾” la capătul frontal pentru montare prin inserție.
Aceste sonde sunt compatibile cu controlerul universal de proces HI510.
Disponibil cu senzor de platină sau aur.
Alegeți joncțiune ceramică standard sau joncțiune PTFE rezistentă chimic.
Sondă digitală care este detectată automat și transmite date prin conexiune RS485.
Durata de livrare: 1
A Worldwide Leader in Electrode Manufacturing
Since the beginning of the 1990’s Hanna has been a leader in the research & development of ORP electrode technology. The HI2000 series of digital ORP probes represent the continual evolution of the technology. The HI2000 series perform all measurements within the probe and then transfer the data digitally to a process meter with a digital probe input.
The use of digital sensors allows for a process meter to be updated measuring a different parameter without changing controllers. This technology allows for a facility that has multiple control points to only have to maintain a single version of a controller.
The other advantage is that the digital transmission of measurement data is immune to electrical noise generated by motors, pumps, and humid environments. The digital signal can be transmitted over very long distances. The HI2000 series of digital probes are available with cable lengths up to 50 meters.
All Hanna industrial digital ORP electrodes are combination type, i.e. the reference half cell and the measurement half cell are assembled in the same body. All of the probes are made with a chemically resistant PVDF body and have a pt100 temperature sensor.
In many industrial applications there is a potential for a ground loop. This can happen when the ground of the process line is different than the ground of a controller/transmitter.
When a traditional electrode/controller system is used, the electrode reference is connected from the electrode to the instrument and current can flow through the reference half cell, causing fluctuations in reading and serious damage to the Ag/AgCl element. The potential matching pin shields the reference from external electrical fields. Shown above, the matching pin allows the measurement to stabilize and ensures effective process regulation. In order to function properly, the matching pin has to be continuously immersed in the measured solution and for this reason is placed near the electrode junction.
These electrodes have been designed with ¾” external thread for easy installation for in-line applications. HANNA instruments® also provides a series of probe holders for submersion tank installations.
All HI2000 series of digital ORP probes have a built-in 3-wire Pt100 sensor for temperature measurements.
Electrodes are wired for direct connection to the HI510 Universal Process Controller.
HI2000 digital ORP probes are available with a 5, 10, 15, 25, or 50 m of cable.
The PVDF body used for the Flat Tip Series withstands high pressure and high temperature applications, and guarantees a high chemical and mechanical resistance. These characteristics make the PVDF material the most recommended for many industrial applications.
Product Specifications:
Descriere
digital ORP probe with built-in pt100 temperature sensor
Domeniul de măsurare
±2000 mV
Tipul joncțiunii / Rata de flux
double junction
Tipul electrolitului
polymer
Materialul corpului
PVDF
Mediu
-5 to 80 ºC (23 to 176 ºF)
Pin de referință
yes
Presiune maximă
6 bar (87 psi)
Lungime Corpului/Lungime totală
140 mm
Senzor de temperatură
pt100
Diametrul exterior
22.5 mm
Semnal de ieșire
digital RS485
Tip conectare
direct wire connection
Montare sondă
3/4" NPT threaded connection for in-line mounting or submersion mounting with probe holder